LCPM PROTOCOL MANAGER Configuration
CONNECTOR LEGEND
LED INDICATORS
Three LEDs are used to indicate power supply and processor run status and data
receive detection.
Glowing steadily indicates power supply and processor OK; off indicates no
power, and flashing indicates defective processor hardware.
Glowing steadily indicates data 1 signal received; off indicates no signal
present. Note that an address selection out of the range of the data signal
will extinguish the LED.
Glowing steadily indicates data 2 signal received; off indicates no signal
present. Note that an address selection out of the range of the data signal
will extinguish the LED.
RUN
RxD
ERR
ADDRESS SELECTION
Three rotary switches select the offset start address for the unit in most
configurations. For dual AMX output, the address switches select the starting
dimmer number for the second AMX output line. In test mode, the switches set
dimmers to full one at a time. The switches are set as (S1) hundreds, (S2) tens
OPERATING MODE 1 2
BACKUP
ON ON
Input 1 takes priority over 2: input 2 is active on loss of 1
PILE-ON
OFF ON
Highest channel on each input takes precedence
MERGE
ON OFF
Input 2 appended to input 1 for one continuous output stream
TEST MODES (determined by I/O mode)
OFF OFF
Input Test: Receive data LEDs indicate correct data signal (on steadily), faulty or
incorrect signal (flashing), or absence of any signal (off).
Output Test: Desired output protocol transmitted on dimmer selected by Address
Switches. Output set to full or cycled per switch 8.
I/O MODE 3 4
DMX INPUT – DMX OUTPUT ON ON
DMX INPUT – AMX OUTPUT OFF ON
AMX INPUT – AMX OUTPUT ON OFF
AMX INPUT – DMX OUTPUT OFF OFF
DUAL AMX OUTPUT (Functional only in pile-on or backup modes)
7
DUAL AMX OUTPUT ENABLED ON
DUAL AMX OUTPUT DISABLED OFF
STATUS QUO HOLD TIME
5
ENABLED (5 MIN. TIME OUT)
ON
DISABLED (2 SEC. TIMEOUT)
OFF
Maintains last dimmer settings for a set time on loss of input data signal
CALIBRATE MODE
6
D/A OUTPUT ENABLED
Analog output level can be tested at J3-AN1 using a DC voltmeter: no other functions
active
ON
D/A OUTPUT CHECK DISABLED OFF
TEST CYCLE MODE
8
TEST CYCLE ENABLED
Ramps the selected dimmer up and down continuously between zero and full
ON
TEST CYCLE DISABLED
Sets the selected dimmer to full
OFF
DIP SWITCH SETTINGS
rev8 ver3.0
CONNECTOR J1 CONNECTOR J3
COM
INPUT SIGNAL COMMON
V+
+9 to +12VDC @150mA
D1-
DMX1 DATA- / AMX1 CLOCK-
INPUT
COM
POWER SUPPLY COMMON
D1+
DMX1 DATA+ / AMX1
CLOCK+ INPUT
COM
OUTPUT SIGNAL COMMON
AN1
AMX1 ANALOG INPUT
D+
DMX DATA+ / AMX1 CLOCK+
OUTPUT
COM
INPUT SIGNAL COMMON
D-
DMX DATA- / AMX1 CLOCK-
OUTPUT
D2-
DMX2 DATA- / AMX2 CLOCK-
INPUT
AN1
AMX1 ANALOG OUTPUT
D2+
DMX2 DATA+ / AMX2
CLOCK+ INPUT
AN2
AMX2 ANALOG OUTPUT
AN2
AMX2 ANALOG INPUT
CD+
AMX2 CLOCK+ OUTPUT
CD-
AMX2 CLOCK- OUTPUT
JUMPERS
RLY
JP1
FACTORY USE
RELAY DRIVE OUTPUT
Open collector output used with
V+ to drive external relays/
LEDs
JP2-3
FACTORY OPTION USE
JP4-5
Shunt for DMX OUTPUT
Open for AMX OUTPUT
JP6
Open for AMX1 OUTPUT
JP7
RELAY DRIVE OUTPUT
09/03
Printed in Canada
www.pathwayconnect.com
Pathway Connectivity Inc., 480C - 36 Avenue S.E.,
Calgary, AB, T2G 1W4 Canada
tel (403) 243-8110 fax (403) 287-1281